OutBackInverters.Com
 Your number one source for OutBack Inverters and Accessories !
Home Contact us
PSAC And Options
 
 
Up Sealed Inverters Air Cooled Inverters PV Charge Controller System Control Comm Manager PSDC And Options DC Breakers PSAC And Options AC Breakers PSR And Options PSPV And Options PSSB And Options Croc Tough Kits Pathmaker System Pathmaker II System Survivalist System Survivalist II System Extremist System Extremist II System  



Precision Designed And Manufactured In The USA ! 

PSAC/PS2AC

OutBack Power Systems has developed a single box solution for all of the AC components of a renewable energy system. The PSAC saves time, money and space by combining all of the disconnects, overcurrent protection, grounding and transformer components into an easy to install, single enclosure. The PSAC is easily modified and expanded as your system grows or changes.

 


Standard Features and Components 

·          ETL listed indoor type powdercoated steel enclosure

·          Dual snap-in DIN rail type mounting brackets for up to sixteen AC circuit breakers – 15, 20, 25, 30 or 60 amps

·          Available with or without a 30 or 60  amp 120 VAC or 120/240 VAC input/output/bypass disconnect breakers with interlock safety switch to allow AC loads to be powered from the utility or generator even if the inverter/charger is removed from the system for servicing or repair – also available as a kit for easy field installation or upgrading

·          Ground terminal bus bar

·          Isolated neutral terminal bus bar

·          Hot terminal bus bar for connecting additional AC load circuits

·          Designed to mount directly to the AC end of one or two SW or DR series inverters  (Also is easily connected via conduit or raceway to other inverter models)

·         Plenty of room for additional current sensors and control relays for advanced system designs

Optional Components 

·          Additional 30 or 60 amp input/output/bypass disconnects for a second inverter/charger

·          Additional AC input or output breakers for back-up generator or AC loads – 15, 20, 30 or 60 amp

·          X-240 - 4 kW step-up/step-down/generator balancing autotransformer

·          X-Fan - AC cooling fan to increase the autotransformer rating to 6 kW or to ensure efficient operation during high temperature conditions

·          VREA - Adapter plate for direct connection of a PSAC to a Vanner RE inverter/charger

·          PSA – Adapter plate for direct connection of a PSAC to a PS series inverter/charger

Physical Dimensions 

·          PSAC enclosure: 10.5” wide x 9” deep x 32.5” tall  (26.6cm x 22.8cm x 82.5cm)

        ·          Shipping size:  12.75” x 36” x 13.75”     Weight (without options):  32 pounds  (14.5 kG)

 

PSAC-60 PSAC Disconnect with AC input/output/bypass breaker

for one FX, SW or DR inverter/charger - also includes a separate ground, isolated neutral and hot terminal bus bar

LIST PRICE $369.00

PSAC-60D PSAC Disconnect with AC input/output/bypass breaker

for Dual FX or SW series inverter/chargers - also includes a separate ground, isolated neutral and hot terminal bus bars

LIST PRICE $445.00

PSAC-60Q PSAC Disconnect with 60 amp AC input/output breakers and 60 amp 120/240 VAC bypass included

for up to four FX series inverter/chargers - also includes a separate ground, isolated neutral and hot terminal bus bars

LIST PRICE $549.00

PSAC-100Q PSAC Disconnect with 60 amp AC input/output breakers and 60 amp 120/240 VAC bypass included

for four FX2000 series inverter/chargers - also includes a separate ground, isolated neutral and hot terminal bus bars

LIST PRICE $599.00

PS2AC-50D PS2AC Disconnect with DUAL AC input/output/bypass breaker

for one or two FX inverter/chargers ONLY! - includes one ground, one isolated neutral & four hot terminal bus bars one OBAC-15, one OBAC-20, one duplex AC outlet and precut wires to make the connections to the inverters

LIST PRICE $385.00

 

INPUT/OUTPUT BYPASS ASSEMBLIES

 

AC-IOB-60 AC Input/Output/Bypass breaker assembly 60 amp 120 VAC

for adding one OutBack FX2000, SW or DR inverter/charger - requires three breaker spaces – includes safety interlock and terminals for up to #2 to 6 AWG wires. Additional TBB-Rs may be required for 120/240 VAC applications – order separately from below

LIST PRICE $85.00

AC-IOB-60D AC Input/Output/Bypass breaker assembly 60 amp 120/240 VAC

for adding two series stacked inverters requires six breaker spaces – includes safety interlock and terminals for up to #2 to 10 AWG wires. Additional TBB-Rs may be required for 120/240 VAC applications – order separately from below

LIST PRICE $159.00

AC-IOB-30 AC Input/Output/Bypass breaker assembly 30 amp 120VAC

for one PS or other small inverter/chargers for one PS or other small inverter/chargers - requires three breaker spaces – includes safety interlock. Additional TBB-Rs may be required for 120/240 VAC applications – order separately from below

LIST PRICE $85.00

AC-IOB-60Q AC Input/Output/Bypass breaker assembly 60 amp 120/240 VAC

for four FX series inverter/chargers requires nine ½ inch breaker spaces - includes safety interlock and terminals for up to #2 to 10 AWG wires Additional TBB-Rs may be required for 120/240 VAC applications - order separately from below

LIST PRICE $169.00

AC-IOB-100Q AC Input/Output/Bypass breaker assembly 100 amp 120/240 VAC

for four FX series inverter/chargers Same as above except includes a 100 amp bypass breaker instead of a 60 amp

LIST PRICE $219.00

 

PSAC OPTIONS

AC-IOB-100Q 4 kVA 120/240 VAC Auto-Transformer

for step-up, step-down or generator balancing applications includes a 25 amp 2 pole breaker for manual control and overload protection of the transformer and wiring

LIST PRICE $290.00

Give us a call to get your "Down Under Price" and "Out Of This World Service & Support !"

1-866-523-4948

Please note, we are a dealer of OutBack Power products. We are not OutBack Power. Please click on this link if you are attempting to reach OutBack Power's website.


 
Hot Tip
Tools and appliances were designed to run off of pure sine waves not modified sine waves. Running your equipment off of a modified sine wave inverter can make them run hotter and can actually shorten their lives. That's why Outback power designs and builds only Pure Sine Wave inverters.

All in one AC protection
A single box solution for all of the AC components of a renewable energy system.
 